Skip to content

WDG 1200 &1210 (Oxygen)

Une gamme très flexible d’analyseurs d’oxygène de gaz de combustion de haute précision développés spécifiquement pour les applications d’analyse et de contrôle de la combustion.
  • Aperçu +


    Using AMETEK’s industry-proven zirconium oxide sensor technology, the WDG-1200/1210 range provides the world’s first fully-integrated, standalone flue gas oxygen analysers. The user interface is mounted onto the probe, lowering installation costs.

    The unique design allows the sensor assembly to be removed without disturbing the outer protection tube. This means maintenance can be carried out easily on-site, with all parts replaceable in the field, reducing costs and downtime.

    The WDG-1200/1210 offers local control via the simple user interface attached to the probe, with a remote-control unit available for less accessible locations. Advanced communications options allow straightforward integration into plant control systems.

    The WDG-1200/1210 range provides the essential measurements for combustion efficiency, NOx reduction, excess air measurement and pollution control applications in the hydrocarbon processing, industrial processing and power generation industries.

    COMPLETELY FIELD SERVICEABLE
    The inner tube structure, including the sensor assembly and heater, can be completely removed, leaving the outer protection tube in the process. This makes field service fast and easy, without the expensive downtime of a return-to-factory repair.

    SIMPLE, FLEXIBLE OPERATION
    The user interface is mounted onto the probe for local control at the measurement location. For restricted or hostile locations, a remote-control unit is available. Both methods use simple push-button operation and a clear LED display for ease of use.

    VERSATILE PROBE AND MOUNTING
    310 stainless steel probes for the WDG analysers are available in various lengths, with a range of mounting flange options to suit your process. A dust-protection filter at the end of the probe prevents fly ash damage to the sensor.

    The WDG-1200/1210 range is AMETEK Land’s ground-breaking series of flue gas oxygen analysers.
  • Caractéristiques techniques +


    Genesis WDG 1200 and WDG 1210 Sensor
    Measuring Range: From 0 to 1 %, 0 to 25 % O2 v/v 
    Accuracy: ±1 % of measured value or ±0.05% oxygen, whichever is greater 
    Response Time: < 3 secs to calibration gas 63% of a process step change, 20 secs
    Drift: < 0.1 % of cell output per month
    (< 0.005 % O2 per month with
    2 % O2 applied) 
    Linearity: ±1 % of output span 
    Repeatability: ±1 % of output span 
    Probe Lengths: 0.22 m (9 in), 0.45 m (18 in), 0.9
    m (36 in), 1.8 m (72 in) and 2.7 m
    (108 in) 
    Mounting Options: 2” NPT thread, 3” 300 lb ANSI,
    2” 150 lb ANSI, 3” 150 lb ANSI,
    4” 300 lb ANSI, DN65 PN6 (JIS) 
    Max. Flue Gas Temperature: 800 °C (1472 °F) 
    Sample Pressure: ±2 psig (± 13.8 kPa) 
    Environment: Ambient Temp.: -20 to 71 °C (-5 to 160 °F)
    Relative Humidity: 10 % to 90 %,
    non-condensing 
    Calibration Gas Req: Use all calibration gases @ 10 psig, 3 to 6 scfh (0.70 kg/cm2 
    1.41 to 2.82 L/min) O2 Span Gas: Air or from 1.0 % to 100 % O2 
    balance N2, O2 Zero Gas: 2 % or from 0.1 to 10% O2 
    balance N2 
    Calibration: Manual, automatic and remote trigger
    Genesis Probe Control Unit
    Display / Keypad: Single-line 4 digit LED; 4 keys 
    Analog Outputs: Isolated 4-20 mA. Max impedance 500 ohms.
    Current loop isolation is 1000 V rms 
    Alarms: System Fault, Maintenance,
    Calibration In Progress - Single pole form C 2A at 30Vac/dc 
    Communications: Modbus, Isolated RS-485 2-wire 
    Environment: Ambient Temp.: -20 to 71 °C (-5 to 160 °F) 
    Relative Humidity: 10 % to 80 %, non-condensing 
    Enclosure: IP65 
    Power Requirements : Nominal 115-230 Vac ±10 %, 47-63 Hz;
    4 A 6mm female thread for earth grounding 
    System Compliance: EMC directive 89/336/EEC
    Low Voltage Directive 73/23/
    EEC, CE 
    Autocal Unit
    Dimensions: 300 x 200 x 155 mm / 11.8” x 7.9” x 6.1” (H x W x D) 
    Weight: 6 kg / 13.2 lbs. 
    Operating Temp: 0 to 50 °C / 32 - 122 °F  
    Enclosure Rating: IP65 
    Power Supply: Selected to 110 v or 230 v a.c. 50-60 Hz 10VA 
    Supply Tolerance: -10 %, +20 % 
    Gas Inlet Pressure: 25 - 30 psi (1.7 to 2.0 bar) 
    Gas Outlet Flow: 3 to 6 scfh (1.6 to 2.8 l/min) 
    Pressure Switch: 15 psi (1.0 bar) trip pressure 
    Span (Slave) Relays: 2 - galvanically free changeover relay contacts
    Control Interface: Single 8 core hard wire lead to Genesis Control Unit 
    Fuse Rating: 125 mA @ 230v antisurge, 
    250 mA @ 110v antisurge 
    Isolation Switch Rating: 240V 1A (customer supplied) 
    Installation: Category II 
    Overvoltage: Category II 
    PDS241/0914
  • Documentation +